Download Analyzing Biomolecular Interactions by Mass Spectrometry by Jeroen Kool, Wilfried M. A. Niessen PDF

By Jeroen Kool, Wilfried M. A. Niessen

This monograph experiences all correct applied sciences in response to mass spectrometry which are used to check or reveal organic interactions regularly.
prepared in 3 components, the textual content starts through reviewing thoughts these days virtually thought of classical, reminiscent of affinity chromatography and ultrafiltration, in addition to the newest options. the second one half focusses on all MS-based equipment for the examine of interactions of proteins with all sessions of biomolecules. along with pull down-based methods, this part additionally emphasizes using ion mobility MS, capture-compound methods, chemical proteomics and interactomics. The 3rd and ultimate half discusses different vital applied sciences usually hired in interplay experiences, reminiscent of biosensors and microarrays.
For pharmaceutical, analytical, protein, environmental and biochemists, in addition to these operating in pharmaceutical and analytical laboratories.

Show description

Read Online or Download Analyzing Biomolecular Interactions by Mass Spectrometry PDF

Similar analytic books

Extra resources for Analyzing Biomolecular Interactions by Mass Spectrometry

Sample text

This leads to more energetic collisions with the He bath gas, which in turn leads to a gain in ion internal energy and subsequent fragmentation of the excited precursor ion. The various steps of the process are performed one after another in the same space (the ion trap), and can thus be considered to be “tandem-in-time” [72]. The process described can be repeated to achieve multiple stages of MS–MS or MSn (up to 10 stages in most instruments). 2, the ion-trap CID process differs from collisioncell CID: smaller target, RF ion excitation, and longer interaction time.

The charged fragments of metastable ions may be detected, for example, using various linked-scan procedures in double-focusing sector instruments [44, 66]. However, fragmentation may also be induced by activation of selected ions, that is, by increasing their internal energy. The most widely applied method of ion activation is collisional activation. On acceleration and collision of the selected ions with a target gas (He, N2 , or Ar) in a collision cell, the ion translational energy can partially be converted into ion internal energy.

The ion shutter provides pulse-wise introduction of ions into the drift tube, in which a uniform axial electric field gradient (typically 1–1000 V cm−1 ) is maintained with a series of guard rings, separated by electrically insulating spacers and connected with an appropriate precision resistor network. The IMS measures how fast a given ion moves through the buffer gas (He, N2 , or Ar) in a uniform electric field, and can thus be used to determine (reduced) ion mobility from the drift time. IMS may be considered being gasphase electrophoresis.